Technical Data Input voltage 1: 3-phase 360–440 V AC, 50 Hz Input voltage 2: single-phase 207–253 V AC, 50 Hz Output voltage: DC 24 V Output power: 2×8.5 kW / 2×3 kW Isolation type: High-frequency transformer isolation Efficiency: ≥94 % Protection class: IP66 Dimensions: 1561×718×550 mm Weight: 340 kg (carbon steel housing) Communication: Ethernet, RS232 (maintenance) Ambient temperature: -25 °C to +45 °C Cooling type: Forced-air cooling (active, with fan) Functional description When powered from the vehicle's internal supply, the unit converts a three-phase AC voltage of 400 V/50 Hz into a galvanically isolated 24 V DC voltage. When powered from the platform/depot supply network, it converts a single-phase AC voltage of 230 V/50 Hz into the same galvanically isolated 24 V DC voltage. The 24 V DC output supplies the vehicle battery and DC loads (output voltage varies with battery temperature). Application Used in series production on the ALSTOM/SBB H4 locomotive.
Technical Data Input voltage: 3-phase 415 V AC, 50 Hz (range 379.15–435.75 V) Output voltage: DC 120 V (range 115–125 V) Output current (rated): 29 A, max. 35 A (to zu 60 s) Output power: 3.5 kW Efficiency: >90 % Isolation type: galvanische Trennung mittels Mittelfrequenztransformator Dimensions: 650×350×1950 mm Weight: <140 kg Cooling type: Natural cooling (passiv) Application Diesel locomotive (in service in Sudan, 17 units installed).
Technical Data Input voltage: single-phase 230 V AC (50 Hz ±1 Hz), range 190–270 V AC Output voltage: DC 24 V Output power: 3 kW Efficiency: ≥ 94 % Protection class: IP20 Dimensions: 483 × 416 × 177 mm Weight: 21 kg Cooling type: Forced-air cooling Application Used in series production in the ALSTOM Coradia LINT diesel multiple unit (DMU), supplying the vehicle batteries and 24 V DC loads.
Technical Data Input voltage 1: 3-phase 300–560 V AC, 50 Hz ±1 Hz Input voltage 2: single-phase 275–520 V AC, 50 Hz ±1 Hz Output voltage: DC 110 V Output power: 3.3 kW Efficiency: ≥ 96 % Protection class: IP54 Dimensions: 350 × 300 × 136 mm Weight: 13 kg Cooling type: Forced-air cooling Application Widely used in Chinese diesel locomotives, supplying the vehicle batteries and DC loads.
Technical Data Input voltage: DC 750 V (range DC 450–1000 V, from the overhead line) Output voltage, mode 1: DC 1000 V (range DC 750–1000 V), 22 kW Output voltage, mode 2: DC 800 V (range DC 550–800 V), 35.2 kW Charging current (fast charge): 22 A ±2 A / 44 A ±2 A Efficiency: ≥ 93 % Protection class: IP65/IP54 Dimensions: 840 × 536 × 528 mm Weight: ≤ 120 kg (aluminum alloy) Cooling type: Forced-air cooling Application Used in the ALSTOM Nice Citadis tram, charging the vehicle battery from the overhead line.