Technical Data Rated input voltage: 24 V DC Input voltage range: 16.8~30.5 V Rated output voltage: Einphasig 142 V Input voltage range: 134.9~218.4 V Rated output frequency: 30 Hz Rated output power: 857 VA Rated output current: 3.48 A Rated output power: 600 W Cooling type: Natural cooling Dimensions: 520 × 128 × 318 Weight: ≤ 16 kg Application Metro Edmonton
Technical Data Rated input voltage: 60 V DC Input voltage range: 50–90 V Rated output voltage: 3-phase 380 V/60 Hz Rated output power: 1.9 kVA Rated output current: 2.9 A Rated output power: 1.5 kW Cooling type: Natural cooling Dimensions: 690 × 216 × 57 Weight: ≤ 13.5 kg Application Metro Brazil
Technical Data Rated input voltage: 72 V DC Input voltage range: 50–90 V Rated output voltage: 3-phase 182 V Rated output frequency: 50 Hz Rated output power: 0.8 kVA Rated output current: 2.54 A Rated output power: 528 W Cooling type: Natural cooling Dimensions: 500 × 200 × 250 Weight: 25 kg Application Metro Mexico
Technical Data Rated input voltage: 72 V DC Input voltage range: 50–90 V Rated output voltage: 3-phase 182 V Rated output frequency: 50 Hz Rated output power: 840 VA Rated output current: 2.6 A Rated output power: 555 W Cooling type: Natural cooling Dimensions: 500 × 200 × 317 Weight: ≤ 25 kg Application Metro Panama
Technical Data Rated input voltage: 110 V DC Input voltage range: 77–137.5 V Rated output voltage: 3-phase 210 V Rated output frequency: 35 Hz Rated output power: 1 kVA Rated output current: 2.7 A Rated output power: 0.75 kW Cooling type: Natural cooling Dimensions: 350 × 301 × 150 Weight: ≤ 14 kg Application Metro Chennai, India India
Technical Data Rated input voltage: 110 V DC Input voltage range: 77–137.5 V Rated output voltage: 3-phase 220 V Rated output frequency: 35 Hz Rated output power: 2.5 kVA Rated output current: 6.6 A Rated power: 1.8 kW Cooling type: Natural cooling Dimensions: 550 × 220 × 200 Weight: ≤ 20 kg Application Metro AnPang
Technical Data Rated input voltage: 110 V DC Input voltage range: 77–137.5 V Rated output voltage: 3-phase 415 V Output voltage range: 405–425 V Rated output power: 3 kVA Rated output current: 4.2 A Max. output current: 5.02 A (to zu 60 s) Cooling type: Natural cooling Dimensions: 650 × 350 × 1950 Weight: < 80 kg Application Diesel locomotive Sudan
Technical Data Rated input voltage: 110 V DC Input voltage range: 70–115 V Rated output voltage: 3-phase 360 V Rated output frequency: 50 Hz Rated output current: 2.3 A Rated power: 1.33 W Cooling type: Natural cooling Dimensions: 785 × 495 × 209 Weight: ≤ 35 kg Application High-speed train Korea
Technical Data Rated input voltage: 110 V DC Input voltage range: 77–137.5 V Rated output voltage: 3-phase 380 V Rated output power: 1.43 kVA Rated output current: 2.2 A Rated power: 1 kW Cooling type: Natural cooling Dimensions: 600 × 227.5 × 100.5 Weight: 13 kg Application Metro Manila
Technical Data Rated input voltage: 110 V DC Input voltage range: 77–137.5 V Rated output voltage: 420 V AC Rated output frequency: 48 Hz Rated output power: 3 kVA Rated output current: 4.1 A Rated power: 2.2 kW Cooling type: Natural cooling Dimensions: 530 × 265 × 238 Weight: <20 kg Application Metro Singapore
Technical Data Rated input voltage: 440 V AC Input voltage range: 356.4–541.2 V Output 1 Rated output voltage: 3-phase 440 V Output voltage range: 425–455 V Rated output frequency: 60 Hz Rated output current: 30.88 A Rated output power: 20 kW Output 2 Rated output voltage: 3-phase 440 V Output voltage range: 425~455 V Rated output frequency: 60 Hz Rated output current: 13.12 A Rated output power: 8 kW Other Protection class: IP54 Cooling type: Forced-air cooling Dimensions: 280 × 110.5 × 216 Weight: 10.5 ± 0.5 kg Application AC express multiple unit Japan
Technical Data Input voltage 2: 4 V DC Input voltage range: 16.8 to 30 V DC Output voltage: 1P 230 V ±5 % Output frequency: 50 Hz ±0.5 Hz Output power: 1 kVA Isolation method High-frequency Transformer isolation DC-Ausgangsleistung 15 kW Efficiency: ≥94 % Protection class: IP20 Dimensions: 483 × 416 × 132 mm Weight: 18 kg Communication mode: RS232 maintenance Ambient temperature: -25 °C to +70 °C Application Widely used in ALSTOM Coradia LINT multiple units.
Technical Data Rated input voltage: 74 V DC Input voltage range: 56–84 V Rated output voltage: Einphasig 220 V Rated output frequency: 50 Hz Rated output power: 3.7 kVA Rated output current: 16.8 A Rated power: 3.5 kW Cooling type: Forced-air cooling Dimensions: 515 × 300 × 250 Weight: ≤ 60 kg Galvanic isolation between input and output via medium-frequency transformer Application Diesel locomotive LC-CKD9D South Africa
Technical Data Input voltage range: 1200–1700 V DC (the input voltage is derived from two isolated DC busbars of the main transformer) Rated input voltage: 3-phase 380 V ± 7 % Output voltage waveform: Sine wave 3-phase output current: 759.7 A N-phase current: 182 A Rated input frequency: 50 Hz ± 1 Hz Rated output power: 500 kVA Efficiency: ≥90 % Protection class: IP54 Cooling type: Liquid cooling Weight: ≤1240 kg Dimensions: 1100 × 1060 × 2100 Galvanic isolation between input and output via high-frequency transformer Application Diesel locomotive Morocco