Product information "Auxiliary Converter APS1500DC/921DC/60kW"
Technical Data
Auxiliary inverter
- Rated voltage: 1500 V DC (1000–2000 V, from the overhead line)
- 800 V DC (600–940 V, from the traction battery)
- Output voltage: 3-phase 380 V ±5 %
- Rated output current: 122 A
- Output power: 80 kVA
Traction battery charger
- Rated voltage: 1500 V DC (1000–2000 V, from the overhead line; 3-phase 380 V (361–399 V) (from the depot)
- Rated output voltage: 921 V DC
- Max. output voltage: 940 V DC
- Rated output current: 64 A
- Rated output power: 60 kW
24 V charger
- Rated input voltage: 3-phase 380 V (361–399 V)
- Rated output voltage: 24 V DC (18–28 V)
- Max. output current: 300 A
- Rated output power: 7.2 kW
- Efficiency: ≥90 %
110 V DC auxiliary power supply
- Rated input voltage: 24 V DC (18–32 V)
- Rated output voltage: 110 V DC (77–137.5 V)
- Rated output current: 4.5 A
- Output power: 500 W
Other
- Cooling type: Forced ventilation
- Dimensions: 1680 × 750 × 1800
- Weight: ≤ 1550 kg
Galvanic isolation between input and output via medium-frequency transformer
Application
- GCD-300
Battery maintenance for locomotives
- Malaysia
| Cooling Method: | Forced-air cooling (active) |
|---|