Skip to main content Skip to search Skip to main navigation

Auxiliary Converter APS 480AC/3P 415AC/365kW

(Abb. ggf. ähnlich oder abweichend)

Product information "Auxiliary Converter APS 480AC/3P 415AC/365kW"

Technical Data

Train power supply/inverter module

  • Rated input voltage: 3-phase 480 V ±5 %
  • Rated output voltage: 3-phase, 4-Leiter 415 V ±5 %
  • Rated output current: 600 A
  • Rated output power: 365 kW
  • Rated output capacity: 430 kVA

Excitation module

  • Rated input voltage: 110 V DC (77–137.5 V)
  • Rated output voltage: 72.8 V DC
  • Rated excitation current: 5.64 A
  • Max. output voltage: 0.96*Ui

Other

  • Cooling type: Forced ventilation
  • Dimensions: 1050 × 640 × 2507
  • Weight: ≤1000 kg

Application

  • Diesel locomotive
  • Nigeria
Cooling Method: Forced-air cooling (active)