Skip to main content Skip to search Skip to main navigation

Auxiliary Converter APS 3P 73~220AC/3P 146~440AC/110A

(Abb. ggf. ähnlich oder abweichend)

Product information "Auxiliary Converter APS 3P 73~220AC/3P 146~440AC/110A"

Technical Data

Excitation module for main and auxiliary generator

  • Input voltage: 3-phase 73–220 V (from the generator)
  • Input current: Max. current per phase 160 A
  • Output voltage: Main generator excitation 32 V DC, Auxiliary generator excitation 30 V DC
  • Output current: Main generator excitation 140 A, Auxiliary generator excitation 105 A

Battery charging module

  • Input voltage: 3-phase 146–440 V
  • Rated output power: 26 kW
  • Output voltage: 74 V DC (70.5–78.5 V)

Inverter module for air-conditioning compressor

  • Input voltage: 3-phase 146–440 V (from the generator)
  • Output voltage: 3-phase 135 V ±5 %
  • Output current: 110 A

Inverter module for fan

  • Input voltage: 3-phase 146–440 V (from the generator)
  • Output voltage: 3-phase 432 V ±5 %
  • Output current: 47 A

Other

  • Cooling type: Forced-air cooling
  • Dimensions: 630 × 1350 × 2050
  • Weight: 1000 kg

Galvanic isolation between input and output via medium-frequency transformer

Application

  • Shunting
  • Locomotive
Cooling Method: Forced-air cooling (active)