Product information "Auxiliary Converter APS 3P 73~220AC/3P 146~440AC/110A"
Technical Data
Excitation module for main and auxiliary generator
- Input voltage: 3-phase 73–220 V (from the generator)
- Input current: Max. current per phase 160 A
- Output voltage: Main generator excitation 32 V DC, Auxiliary generator excitation 30 V DC
- Output current: Main generator excitation 140 A, Auxiliary generator excitation 105 A
Battery charging module
- Input voltage: 3-phase 146–440 V
- Rated output power: 26 kW
- Output voltage: 74 V DC (70.5–78.5 V)
Inverter module for air-conditioning compressor
- Input voltage: 3-phase 146–440 V (from the generator)
- Output voltage: 3-phase 135 V ±5 %
- Output current: 110 A
Inverter module for fan
- Input voltage: 3-phase 146–440 V (from the generator)
- Output voltage: 3-phase 432 V ±5 %
- Output current: 47 A
Other
- Cooling type: Forced-air cooling
- Dimensions: 630 × 1350 × 2050
- Weight: 1000 kg
Galvanic isolation between input and output via medium-frequency transformer
Application
- Shunting
- Locomotive
| Cooling Method: | Forced-air cooling (active) |
|---|